The cylinder retracts during injection

Problem: a core cylinder with 10 mm stroke slowly moves back after a few cycles; the effect changes with the plastic material.

  1. Verify the sizing: injection pressure on the core, effective area, required force, locking capacity.
  2. Check that the preload is set correctly.
  3. Measure the real movement with a dial gauge: size, timing, repeatability.
  4. Check flanges, fixings and mechanical stops.
  5. Check the check valve: type, position, rigid connection to the cylinder.
  6. Measure the hydraulic pressure at the cylinder, not only at the machine.
  7. Map when the pressure is held, reduced or released during injection and holding.
  8. Compare process conditions between materials.
  9. Compare the flash thickness with the measured movement.
  10. Replace components only after measuring.

More force is not automatically better. Preload compensates elastic deformation and small clearances; releasing the hydraulic pressure during injection can make the problem worse.

A self-locking cylinder loses its end-of-stroke signal

Problem: the cylinder reaches the return position and the signal is correct, but after 5–10 seconds the signal drops and the cylinder moves slightly.

  1. Replace the flexible hose between cylinder and check valve with a rigid connection.
  2. Bleed all air from the circuit.
  3. Check the valve for internal leakage.
  4. If the circuit is sound, check the piston seals.
  5. Verify the cylinder reaches the true end position and locks correctly.
  6. Check the sensor last.

Repeated sensor failures

Problem: position sensors fail again and again. Analysis of returned sensors showed liquid inside the housing, corrosion on the leads and incomplete sealing between body and cover.

  • Find the source of the liquid: hydraulic oil, release agent, cleaning fluid, condensation or water.
  • Use sensors with fully encapsulated electronics and continuous sealing.
  • A sensor that passes a function test can still be damaged inside.

Special cylinder for a non-magnetic application

Requirement: a cylinder with no magnetic materials. Base: V250CE short-stroke block cylinder, adapted.

PartSolution
BodyERGAL aluminum alloy
Cartridge, rod, piston, capsAISI 316 stainless steel
SealsSpecial polyurethane, max. approx. 90–100 °C
Oil ports1/4″ BSPT tapered, both sides
Check valveMounted directly on the cylinder with a rigid connection
CertificatesEN 10204 3.1 for body, steel parts and seals

Max. working pressure 150 bar.

Shorter stroke without a new cylinder

Requirement: reduce the stroke of a cylinder from 20 mm to 10 mm.

Solution: a spacer in Ergal aluminum alloy limits the stroke of the existing cylinder.

Seals fail early in a hot mold

Problem: a V450CM block cylinder leaked after about 1.2 million cycles, with unstable holding force. The mold ran at 80 °C.

  • Pressure spikes: the nominal 250 bar rose to about 340 bar during deceleration and extruded the seals through a 0.28 mm gap.
  • Real seal temperature: where the rod touches hot plastic, the seal zone exceeded 90 °C; oil was at about 69 °C.
  • Surface: the sealing surface was rougher than the Ra 0.8 µm limit of the seal.

Solution: extrusion gap reduced from 0.28 to 0.12 mm, NBR replaced by HNBR, cushioning optimized and oil cooling improved. Seal life increased by about 210% and the leakage stopped.

The injection force exceeds the locking cylinder

Problem: a core with a projected area of about 236 cm² must be held at 500 bar cavity pressure: about 118,000 kgf. The locking cylinder is rated 70,000 kgf without preload.

  1. Calculate the force from projected area and cavity pressure, not from the hydraulic pressure.
  2. Compare it with the locking capacity of the cylinder.
  3. If it is higher, a bigger cylinder or more preload is not the answer: the mold needs its own mechanical locking.
  4. Let the cylinder move and position the slide; let the mold structure carry the injection load.

Oil leaks from an NPT port

Problem: a 1/4″ port kept leaking even with sealant. The cylinder had NPT ports; the connection had been specified only as “1/4 inch”.

  • NPT and BSP are not interchangeable, even with the same nominal size.
  • Sealant cannot fix incompatible or damaged threads; over-tightening makes it worse.
  • A port machined in the body often cannot be converted: in this case the body had to be replaced.

Specify the full thread standard, size and sealing method before the cylinder is made.

The rod breaks after many cycles

Problem: the rod and cartridge of a slide cylinder cracked. The cylinder was rigidly fixed with four screws and rear oil ports.

  1. Check that the cylinder axis matches the slide travel over the whole stroke.
  2. Check slide guides, plates, stops and fixing screws for play or interference.
  3. Check the mold opening and closing sequence.
  4. Only then evaluate pressure, flow and timing.

Misalignment adds side force and bending to every cycle and leads to fatigue cracks. An identical replacement in the same setup will fail again.

A cylinder cracks below its rated pressure

Problem: a positioning cylinder working at 100 bar cracked after some weeks, with no overload visible on the gauge.

  1. Record the pressure with an electronic transducer and fast data acquisition: a mechanical gauge misses transients.
  2. The recording showed a spike of about 180 bar, lasting about 100 ms, in every injection cycle.
  3. Source: one pump and servo valve fed several functions, so the injection pressure wave reached the cylinder.
  4. Fix: a check valve isolates the cylinder during injection, and the pressure hold stops once the cylinder is in position.

Replacing the cracked cylinder without removing the source of the spikes leads to the same failure.

A locking cylinder releases on a servo-hydraulic press

Problem: on a servo-driven injection machine the pump stops when full power is not needed, and the self-locking cylinder no longer holds the slide.

  • The cylinder was correctly sized: the cause was the pump control logic.
  • A pilot-operated check valve mounted on the cylinder traps the oil and holds the piston with the pump off.
  • All air must be bled from the circuit before production.

No change to the cylinder, the locking mechanism or the mold was needed.

Ejector cylinder tubes deform

Problem: four identical tie-rod cylinders on an ejector plate, rated 215 bar and supplied at 160–180 bar, all deformed in the same way.

  • Same damage on all four cylinders: a system cause, not a manufacturing defect.
  • The mold could close while the cylinders were still extended and pressurized: the clamping force pushed the plate back and compressed the trapped oil, multiplying the pressure.

Solution: retract the cylinders before mold closing, add safety interlocks, confirm the position with sensors (not only by software) and fit pressure relief where trapped chambers cannot be avoided.

Flash in a zinc die-casting mold

Problem: two compact cylinders (60 mm stroke) holding a slide moved back slightly during injection and left 0.03 mm of flash. Check valves and machine settings had not solved it.

  1. Measurements: supply 125 bar, peaks of about 135 bar in the rear chamber during injection.
  2. Cause: oil compressibility (roughly 1% volume per 160 bar), increased by air and water-glycol fluid; flash on one side only also pointed to uneven support of the slide.
  3. Options: larger bore, a pressure intensifier, or a positive mechanical lock in the mold; linear transducers to monitor position precisely.

Threaded caps need twice the expected force

Problem: a 16-cavity unscrewing mold releases 64 caps per cycle with four cylinders. The calculation used only the smooth lateral surface of the caps: about 6,860 kgf in total, so bore 50 at 85 bar looked sufficient.

Check: including the thread flanks, the contact area per cap rose from 7.1 to about 13.4 cm² and the force to about 12,860 kgf (3,216 kgf per cylinder).

Solution: bore 63 cylinders with 28/36 mm rod at 140 bar. See the unscrewing sizing guide.

The self-locking cylinder does not lock during injection

Problem: on one of two new self-locking cylinders in a mold, the pressure in the cylinder chamber rose during injection and the “forward” signal was lost. Sizing was correct; shimming to complete the stroke changed nothing.

  1. Check that the rod reaches the internal shoulder.
  2. Compare the cylinder with an identical second cylinder on the same mold.
  3. Send the cylinder to our plant to check the internal dimensions.

Solution: the inspection found an internal dimension out of tolerance; with the design corrected and the cylinder replaced, the mold trial was successful. A spare cylinder was supplied meanwhile so production did not stop.

Excessive preload after changing a flange

Problem: on four self-locking cylinders one neutral flange measured 31.27 mm instead of 32.00 mm: 0.73 mm difference.

  1. Measure every flange before mounting and compare it with the drawing.
  2. Find the “zero” with the rod fully extended and Prussian blue on the core.
  3. Determine the preload needed and check flash on molded parts.
  4. Check that the cylinder unlocks correctly.

Solution: with a neutral flange preload can only be obtained by grinding the flange; with the adjustable flange the cylinder is rotated and the problem does not occur. Circuit: constant 120 bar on the push side or a pilot-operated check valve on the cylinder with a rigid fitting, air bled.

Magnetic sensors not reading at 120 °C

Problem: on two short-stroke block cylinders the magnetic sensors worked with the mold cold but not in production, at about 120 °C.

  • The magnetic field changes with temperature: operation is guaranteed up to 80 °C.
  • A heat-insulating plate could not be used because oil was fed through the plate with O-rings.

Solution: cylinder with mechanical limit switches up to 180 °C, pre-wired with silicone cable, with a cam on the rod; alternatively a cylinder with integrated cooling.

Maintenance every 10 days in die casting

Problem: cylinders on the fixed half of an aluminium die-casting mold: seals degraded from heat and maintenance was needed almost every 10 days, with the mold removed, cooled and reheated.

Solution: cylinders with a cooled cartridge (R version), which lowers the body temperature by about 50 °C using the cylinder’s own fluid at low pressure. The first maintenance came after more than 8 months.

Press faults with the microswitch signal

Problem: on new cylinders the press faulted when receiving the signal; the cable was loose in the gland and the metal braid was suspected of shorting to ground.

  1. Check the cable clamping in the gland and the protection where the cable is cut.
  2. Check the press input type and how the braid is connected.
  3. Limit stress on the cable; in critical environments use silicone cable.

Solution: a connection procedure shared with the customer and a cable suited to the environment.

Liquid inside dozens of microswitches

Problem: repeated failures of many microswitches from the same batch, with liquid inside the housing.

  1. Analyse opened samples to find the entry point.
  2. Identify the liquid.
  3. Check the sealing between the two housing halves.

Solution: sealant was not applied evenly during assembly. The supplier’s process was corrected and later permeability tests showed no infiltration. Parts were not replaced en bloc before the cause was known.

Microswitch actuated wrongly because of the wrong bracket

Problem: on four cylinders the actuating shaft did not work correctly, with an offset of about 5 mm.

Solution: a bore 32 cylinder carried the bracket for bore 40. Once the correct parts were sent the problem disappeared without replacing the microswitch. Always check the chain cylinder → bracket → shaft → sensor and measure after mounting.

Oil ports from 3 to 6 mm on installed cylinders

Problem: a customer wanted to double the oil port diameter of compact bore 80 cylinders to increase speed.

  • The rear port is close to the piston guide ring, the front one to the cartridge.
  • v = Q/A: a larger port only helps if it is the real restriction in the circuit.

Solution: rear passage ovalized by CNC milling and cartridge chamfer modified, machined in our plant in batches in about two days.

Misalignment between cylinder and slide

Problem: the cylinder axis did not match the guided slide axis exactly; the rigid connection transferred the error to the rod.

Solution: DFA floating joint with female counterpart, chosen by rod thread and diameter, for a floating connection. A DFA on a standard rod is not equivalent to a rod with an integrated joint: with high loads a check is needed.

Cylinder selection with a gear mechanism

Problem: choosing the cylinder for a slide driven through gears (PP, shrinkage 1.016%).

  1. F = P × A gives only the theoretical force: the transmission changes force, speed and stroke.
  2. Use the pressure really available during the movement.
  3. Check push and pull: the rod reduces the pull area.
  4. Check real stroke, speed, envelope and the sensor input.

Solution: tie-rod cylinder bore 40 checked at a minimum working pressure of 120 bar, with bore 50 as an alternative. Oversizing increases envelope, oil use and cost.

Core that must resist 24 tonnes

Problem: core with 80 cm² projected area in PP, cavity pressure 300 bar: about 24,000 kgf.

Solution: self-locking cylinder sized by our technical office with a safety margin, first trial on bore 56 with bore 71 as an alternative. For even higher loads a medium-size self-locking cylinder is combined with wedges in the mold.