Frequently asked questions
Technical answers for mold designers and mold makers: sizing, self-locking, temperatures, fluids, materials, sensors and installation.
Choosing and sizing
How do I choose the right cylinder for my mold?
How do I calculate the force of a hydraulic cylinder?
Angle pins or a hydraulic cylinder: which should I use?
How fast can a mold cylinder move?
Which oil port size should I choose?
Can I order a special stroke or special mounting?
How do I size a cylinder that must hold a core against injection pressure?
Does a harder plastic need a bigger cylinder?
How do slide angle and friction affect the choice?
Why do larger bores have a lower maximum pressure?
Aluminum or steel body: which should I choose?
Aluminum-alloy block cylinders (such as V250CE and V220CC) weigh only a little more than one third of steel ones and resist corrosion thanks to anodizing; they suit light to medium duty. Steel block cylinders (such as V450CM) take higher pressures, higher temperatures and shock loads, and have better fatigue resistance for millions of cycles.
| Typical values | Aluminum body | Steel body |
|---|---|---|
| Max. temperature | about 100 °C | 160 °C |
| Pressure | 220–250 bar | higher, see series data |
| Sensors | magnetic | mechanical |
| Weight | light | heavy |
How do I calculate the force needed to pull a core out of the part?
Often the largest load is not the cavity pressure but the adhesion of the shrinking plastic on the core. For a cylindrical core: contact area = π × diameter × contact length; adhesion force = contact area × adhesion coefficient.
| Draft angle | Plastic core (kg/cm²) | Aluminum (kg/cm²) |
|---|---|---|
| 0° | 30 | 80 |
| 1° | 25 | 50 |
| 2° | 20 | 40 |
| 3° | 15 | 30 |
Example: core Ø20 mm, 50 mm contact length, 1° draft → 31.4 cm² × 25 kg/cm² ≈ 785 kg, before adding slide and guide friction and a safety margin. Removing the draft for aesthetic reasons can double the pulling force.
How do I size a cylinder for an ejector plate?
How do I size cylinders for threaded parts?
Can I replace hydraulic cylinders with electric actuators?
Self-locking cylinders
How does a mechanical self-locking cylinder work?
Why does a self-locking cylinder need preload?
My cylinder moves back during injection. What should I check?
Why can the locking segments of a self-locking cylinder break?
My servo-driven press stops the pump. Will the locking cylinder stay locked?
Operating conditions
What is the maximum operating temperature?
What is the maximum working pressure?
Which hydraulic fluid should I use?
Can I run a hydraulic cylinder with compressed air?
The mold runs at 80 °C. Why do the seals fail as if it were hotter?
What limits the temperature of a limit switch?
Can a hydraulic cylinder work in a 200 °C mold?
Can the cylinders be used in ATEX areas?
Why does a cylinder move slightly back under injection even with a check valve?
Materials and maintenance
Which materials are used for body and rod?
How long do the seals last, and what causes leakage?
How do I adjust the cushioning without damaging the seals?
Several cylinders do not move together. Why?
A cylinder cracked below its rated pressure. How is that possible?
How do I detect internal leakage?
Why did the tubes of my ejector cylinders deform?
Sensors and wiring
Which position sensors are available?
How do I wire a 3-wire sensor?
My press has only two-wire inputs. Can I connect the sensors?
Hall-effect sensor or reed switch?
What is the minimum stroke for two position sensors?
Installation
How do I avoid misalignment between cylinder and slide?
Where should I mount the check valve?
Is there a limit to rack length in unscrewing systems?
NPT or BSP ports: can I mix them?
Why can misalignment break a cylinder?
Which tightening torque should I use for tie-rod cylinders?
Self-locking cylinders: preload, mounting and adjustment
How do I set the preload of a self-locking cylinder step by step?
1) Mount cylinder and flange outside the mold, not partly recessed: you need room for the open-end wrench on the cartridge and for rotating the cylinder. 2) Extend the rod and check the “zero”: the core must close on the cavity; check the contact with Prussian blue. 3) Determine the required preload without exceeding the table maximum for bore and stroke. 4) With the adjustable flange, rotate the cylinder to the required value; with a neutral flange preload can only be obtained by grinding the flange. 5) Mold parts and check for flash: if flash grows as preload increases, preload is too high. 6) Always check that the cylinder unlocks correctly.
Is preload always necessary?
No. Preload is needed when flash on the finished part must be avoided, because it compensates rod elasticity and small clearances. Otherwise the self-locking cylinder works correctly without preload. It is an advantage anyway: angle pins and conventional cylinders cannot preload the core.
Can half a millimetre of difference on a flange cause problems?
Yes. In a real case one neutral flange was 0.73 mm thinner than the other three (31.27 mm instead of 32.00 mm): enough to shift the cylinder and create excessive preload. Preload works in hundredths of a millimetre because steel is very stiff. Measure every flange before mounting and compare it with the drawing; an adjustable flange avoids the problem altogether.
What happens if the rod does not reach its end stop?
Mechanical locking only engages when the rod reaches the front end of stroke, seated against the internal shoulder. If the mold stops the stroke earlier, holding force is not guaranteed: during injection the pressure in the chamber rises and the “forward” signal is lost. Check that the cylinder stroke is complete and that no mold stop acts first.
Do the V270CG sensors need adjusting?
No. The inductive sensors sit inside the cylinder chamber, withstand hydraulic pressure and are positioned at the factory after internal tests. There is nothing to set during mounting and switching stays constant over time.
Can I use a self-locking cylinder with water-glycol?
With mineral oil there are no issues. Water-glycol reduces friction and can change the behaviour of the locking sectors, so for self-locking cylinders we recommend mineral oil. If your system runs on water-glycol, contact our technical office before ordering.
Locking in the body or on the rod: which is better?
In our self-locking cylinders the sectors engage a groove machined in the body and the rod is not weakened. For the same bore the load-bearing surface is larger (about 25% more on bore 45 with rod 32 than locking on the rod) and the radial envelope stays small, a decisive advantage in molds. Body locking needs pressure held during locking, which a pilot-operated check valve solves.
Does a self-locking cylinder use less energy than a conventional one?
Yes, often much less. Example: to resist 100 kN a self-locking bore 36 is enough, while at 140 bar a conventional cylinder needs bore 100. With 35 mm stroke at 0.2 m/s that is about 12 l/min and 3.5 kW against about 90 l/min and 26 kW. With a pilot-operated check valve the power needed during injection drops to zero. Real savings depend on the hydraulic circuit.
Is the V260CF still available?
The V260CF is out of production. The V270CG replaces it with the same mounting dimensions, so it also fits existing molds; it is a few centimetres longer because of the longer rod guide, which improves sealing and allows longer strokes and a rod wiper. Bores 30, 36, 45, 56, 71 and 84.
Problems and solutions from our technical office
The end-of-stroke signal drops after a few seconds: where do I start?
First ask whether the cylinder really moved. Then go from simple to complex: replace the hose between cylinder and valve with a rigid connection and bleed the air (two variables removed at once), check the pump-side valve for internal leakage, then the piston seals. Check the sensor last; replacing the cylinder is never the first step.
The rod moves back only with one material (e.g. ABS, not PP): why?
A different material changes process pressures and forces: a mold sensitive to injection loads may run with PP and show flash with ABS. Measure the movement with a dial gauge (even 0.02 mm matters), check preload, type and mounting of the check valve and the pressure sequence against the start of injection. In a real case keeping pressure during injection worked better than releasing it.
Magnetic sensors work cold but not with the mold hot: why?
The magnetic field changes with temperature. Cylinders with magnetic sensors are guaranteed up to 80 °C; at about 120 °C reading is no longer reliable. Solutions: mechanical limit switches up to 180 °C (with a cam on the rod, so room is needed in front of the cylinder), heat-insulating plates where oil is not fed through the plate, or a cylinder with integrated cooling or a cooled double rod.
Can I fit a heat-insulating plate on a cylinder fed through the mold plate?
No. If oil comes from the mold plate through O-rings on the cylinder, an insulating plate would break the oil seal. In that case use a cylinder with integrated cooling or high-temperature mechanical switches.
The press faults when it receives the limit switch signal: what should I check?
Check that the cable is firmly clamped in the cable gland and does not move, that the metal braid does not short to ground where the cable is cut, the press input type (PNP/NPN, NO/NC, voltage) and that the cable is not pulled or bent continuously. In very hot or wet environments prefer silicone cables. Send us the press input specification and a photo of the connection.
Which cables do the MS5, MS6 and MS7 switches have?
MS5: transparent PVC cable with metal braid, Ø6 mm, 3 m. MS6: red silicone cable Ø6 mm, 3 m, for high temperatures. MS7: black PUR cable Ø5.2 mm, 0.2 m, with M12 male connector, plus a 5 m PUR extension with M12 female connector.
I found liquid inside a microswitch: should I replace the whole batch?
Not straight away. First analyse some samples to find where and what entered (oil, release agent, cleaning fluid, condensation). In a real case with dozens of microswitches the cause was uneven sealant at the supplier’s assembly; once the process was corrected, permeability tests showed no further infiltration. Replacing everything without removing the cause repeats the failure.
The microswitch is not actuated correctly on several cylinders: is it faulty?
Often not. When the same fault appears on several cylinders look for a common cause: in one case a bracket for bore 40 had been fitted on a bore 32 cylinder and the actuation point was about 5 mm off. Check that bracket, shaft and sensor match the exact cylinder configuration and measure after mounting.
Can I enlarge the oil ports of a cylinder already installed?
Not recommended on site. The internal passages are close to the piston guide rings and the cartridge: drilling larger can damage internal parts. In one case from 3 to 6 mm on bore 80 we ovalized the rear passage by milling and changed the cartridge chamfer, machined in our plant in about two days per batch. Remember v = Q/A: a larger port only helps if it is the real restriction in the circuit.
Can I shorten the stroke of a standard cylinder?
Yes, in many cases. Example: from 20 to 10 mm with an internal Ergal spacer locked on the rod with a stainless M5 grub screw and Loctite 243, nothing protruding. Stroke tolerance is −0/+0.5 mm. Each solution depends on the configuration: ask our technical office before modifying.
Are non-magnetic cylinders available?
Yes, based on the V250CE: Ergal body, AISI 316 cartridge, rod and plugs, polyurethane seals 90–100 °C, 1/4″ BSPT ports, 150 bar, about 736 kgf push and 354 kgf pull, with EN 10204 3.1 certificates. Define excluded materials and the exact thread standard (parallel BSP or tapered BSPT) from the start.
Is the V250CE suitable for an ejector plate?
No. The V250CE series is not recommended for moving ejector plates or stripper tables or for heavy-duty applications. For ejector plates use V450CM-YES, V450CM, V500CZ or V215CR tie-rod cylinders.
How do I estimate the force for a self-locking cylinder on a core?
Force = projected area of the core × cavity pressure. Real example: 80 cm² in PP at 300 bar gives about 24,000 kgf (about 235 kN). Then choose the bore with a margin and check the maximum preload. Whenever possible send us the drawing: we size the self-locking cylinder with our own safety margins.
Why does integrated cooling extend maintenance intervals?
In die casting, cylinders on the fixed half sit close to the molten aluminium inlet: heat travels from the rod to the seals. In a real case maintenance was needed about every 10 days; with the cooled cartridge (R version), which lowers the body temperature by about 50 °C, the first maintenance came after more than 8 months. In the D version the cooled rod carries coolant straight to the core or slide, with no tubes in the mold.
What temperatures can be reached with water-glycol or with oil and Viton?
As a guide about 140 °C with water-glycol and up to about 160 °C with hydraulic oil and Viton seals, depending on series and sensors. In the cooled cartridge the coolant pressure must stay low (about 10 bar).
Can the customer disassemble a self-locking cylinder?
No. Self-locking cylinders are precision assemblies: they are disassembled in our plant, where sectors, springs and dimensions are checked and the cylinder is tested again. For routine maintenance of other series, replacement cartridges with pre-fitted seals are available.
Spare parts, repairs and service
How do I send a cylinder for repair?
Contact us with a photo of the nameplate (code and serial number) and a short description of the fault, for example “the rod no longer seals”. We confirm shipment and the service department reference; after inspection you receive the diagnosis and, if needed, the repair offer.
Do you supply spare-part kits?
Yes: seals and cartridges for the standard series and, for self-locking cylinders, sector and spring kits per bore. Always state the cylinder code and serial number.
How are the cartridge guide rings fitted?
Bend the guide rings with pliers and place them in their grooves following the position shown in the instruction sheet; take care not to break them while bending.
Do you have an equivalent of another brand’s cylinder?
Send us the drawing or code of the cylinder you use today: our engineers propose the equivalent from our range, if possible with the same mounting dimensions, or a special version (longer rod, opposite oil feed, different stroke).
Do you need urgent help on a mold?
Contact our technical office straight away with photos, cylinder code and a description of the cycle. For critical molds we recommend keeping a spare cylinder in stock: in case of a stop, replacement takes minutes and the diagnosis can be done afterwards.
Hydraulic circuit, valves and pressures
What minimum pressure does a mold cylinder need to work well?
Standard seals work best from about 80 bar upwards. Below that sealing may not be optimal and special polyurethane seals are needed. Self-locking cylinders need at least 100 bar, 120 bar recommended.
Can I size the cylinder on the maximum pressure of the power unit?
No. Use the pressure really available at the cylinder during the movement, measured or guaranteed by the circuit, not the maximum system pressure: valves, hoses and pressure losses sit between power unit and cylinder. Sizing on maximum pressure leads to undersized cylinders in operation.
Pilot-operated check valve or held pressure: which should I choose to hold a core?
If the press keeps constant pressure on the cylinder for the whole injection (120 bar on the push side for self-locking cylinders) the valve is not essential. If pressure drops or the pump stops (servo-hydraulic presses), fit a pilot-operated check valve directly on the cylinder with a rigid fitting and bleed the air.
Why should I not use hoses between check valve and cylinder?
A hose expands under pressure and contains a compressible oil volume: when the injection load arrives the rod can move back a few hundredths and the end-of-stroke signal can drop. With a rigid fitting and the air bled, the elastic volume is kept to a minimum.
How do I bleed the air correctly from a mold cylinder?
Run several full strokes at low pressure and low speed, with the highest ports or fittings in venting position, until oil comes out without bubbles. Repeat after every change of hoses, valves or cylinder. Air increases circuit compressibility and makes the position unstable.
What are pressure spikes and how do I measure them?
They are short overpressures (tens or hundreds of milliseconds) caused by decelerations, valve closing or circuits shared with injection. A mechanical gauge does not see them: you need an electronic transducer with fast acquisition. In real cases 250 bar nominal reached about 340 bar, and 100 bar became 180 bar at every cycle.
The cylinder is pressurized even when idle with the mold closed: is that a problem?
It can be. If the mold closes with the cylinder extended and pressurized, the clamping force compresses the trapped oil and the pressure multiplies, up to deforming the tube. Retract the cylinders before closing, use interlocks and position sensors and fit a relief valve where closed chambers remain.
How do I synchronize two or four cylinders on the same plate?
First balance the circuit: same hose lengths, same fittings, symmetrical manifold and flow regulators close to each cylinder. For strict synchronization use a gear-type flow divider. Flow regulators alone do not guarantee synchronization.
Aluminium and zinc die casting
Which cylinder should I use on an aluminium die-casting mold?
For cores and slides in hot zones: V215CD tie-rod (front seals up to 150 °C, water-glycol compatible) or V450CM with mechanical limit switches up to 180 °C. Where seals degrade from heat: V450CP with integrated cooling. Send us the drawing with the temperature measured at the cylinder.
Can I use water-glycol (HFC) with die-casting cylinders?
Yes: V215CD, V450CM, V450CP and V400CL run on water-glycol. Seal life is shorter than with mineral oil and corrosion increases with temperature and glycol content; for heavy duty specific seals are available. For self-locking cylinders we recommend mineral oil.
Why does the rod yield and leave flash in die casting even with check valves?
Oil compresses by about 1% every 160 bar, more with air or water-glycol: under injection peaks the cylinder can yield a few hundredths. In a zinc mold, peaks of 135 bar with a 125 bar supply produced 0.03 mm of flash. Solutions: larger bore, pressure intensifier or mechanical locking in the mold.
What is the squeeze effect and which cylinder does it need?
Squeeze is local compression of the alloy during solidification to reduce porosity, done with pins that advance into the casting. The V450CP-R cools the front cartridge with a low-pressure circuit (about 10 bar, 3 l/min, coolant up to 150 °C) to withstand the heat of the squeeze pin.
How often is maintenance needed on a die-casting cylinder?
It depends on the real temperature at the seals. On uncooled cylinders near the aluminium inlet we have seen maintenance about every 10 days; with a cooled cartridge the first maintenance came after more than 8 months. Measure the temperature at the seal, not only at the mold.
Ejector plates
How do I calculate the force to move an ejector plate?
Not from the weight of the plates: the main load is the adhesion of the plastic shrinking on the cores. Force ≈ contact area × adhesion coefficient, plus friction and margin. In a real case 129 kg of plates actually needed more than 100 times that force, and two V450CM bore 63 at 140 bar were required.
How many cylinders should I put on a large ejector plate?
On wide plates use 2 or 4 cylinders placed symmetrically, for example at the corners, with a balanced circuit: the push stays even, the plate moves parallel and guides and ejectors wear less.
Must the cylinder stroke match the plate stroke?
Yes. If the mold stops the plate before the cylinder reaches its end of stroke, the load ends up on the rod thread. Match the two strokes and connect the rod with a floating joint to absorb misalignment.
Which series is best for ejector plates?
V450CM-YES (bore 50 and 63, large ports, no protruding screws), V500CZ for very fast cycles up to about 0.8 m/s, V450CM and V215CR tie-rod. The V250CE is not suitable for ejector plates.
Unscrewing threaded parts
How do I calculate the cylinder stroke for rack-and-pinion unscrewing?
Stroke = π × pinion pitch diameter × number of turns, where turns = thread engagement length / pitch. Example: M60 × 5 thread with 20 mm engagement = 4 turns; with a Ø80 pinion the rack travel is about 1,005 mm. Doubling the pitch to 10 mm halves the stroke.
Which safety factor should I use on unscrewing torque?
Design torque = estimated torque × safety factor: 2 for standard applications, 2.5 for automotive, 3 for medical. Then rack force = torque / pinion radius and piston area = force / working pressure.
When is hydraulic unscrewing better than stripping?
Force stripping suits flexible plastics (PP, PE), external threads and short engagement. For PC, glass-filled nylon, internal threads, long engagement, threads above about 50 mm or lights-out production you need unscrewing, and hydraulic unscrewing gives the highest torque.
How often should an unscrewing unit be inspected?
As a guide: leaks and fittings every 500,000 cycles; rack, pinion and rod wear every million cycles; seals and alignment every 3 million.
Quick series selection
What is the difference between a tie-rod and a block cylinder?
A tie-rod cylinder (V215CR, V215CD, UNI-ISO 6020-2) has two heads joined by four tie rods: it is interchangeable with ISO cylinders, easy to service and reaches very long strokes (V215CR up to 2500 mm). A block cylinder has a body machined from one block: it is more compact, takes higher pressures (up to 450–500 bar in steel) and is ideal for short strokes and tight spaces.
Which cylinder for a core with 30 mm stroke and little space?
For short strokes in tight spaces: V250CE (aluminium, 20–80 mm, 250 bar, moderate temperatures) or V450CM (steel, 10–200 mm, 450 bar, mechanical switches up to 180 °C). If space is minimal, the V400CL cartridge is built directly into the plate.
Which cylinder for a 300 mm stroke?
The V220CC block cylinder (65–500 mm, 220 bar) if space is tight, or the V215CR tie-rod (up to 2500 mm, 215 bar) if you want ISO interchangeability. For strokes under 80 mm consider V250CE or V450CM.
Which cylinder holds the core without hydraulic pressure?
The V270CG self-locking cylinder: it locks the rod mechanically in the body at the end of stroke and resists injection pressure. Bores 30–84 mm, 270 bar, integrated inductive sensors, adjustable preload against flash.
Which cylinder for a very fast movement?
The V500CZ: steel block cylinder up to 500 bar with SpeedPorts® oil delivery and cushioning, up to about 0.8 m/s. Without cushioning, mold cylinders should not exceed about 0.1 m/s.
Which cylinder for a very hot mold?
Up to 80 °C magnetic or inductive sensors are fine; above that you need mechanical switches (up to 180 °C: V450CM, V450CP, V500CZ, V215CD). If the issue is seal life, the V450CP with integrated cooling lowers the body temperature by about 50 °C.
Configuration, drawings, delivery and guarantee
Where can I download the 3D drawing of a cylinder?
From the online configurator on vegacylinders.com: choose series, bore, stroke and options, register for free and download the 3D model for your mold design.
How do I read a cylinder code?
The code shows series, bore, mounting and rod end, stroke and options (sensors, cushioning, special versions). The configurator generates the correct code; for a spare part give us the full code and the serial number from the nameplate.
Do you make cylinders to drawing or modified standard cylinders?
Yes: special bores, strokes, mountings, ports, materials, sensors and rods, starting from a modified catalog cylinder or a dedicated design. Send us the 2D drawing or 3D model of the mold: we send a drawing for approval before production.
Is every cylinder tested?
Yes: every cylinder is tested before shipment to guarantee zero oil leakage. Production is followed and inspected directly at HydroSmart Cylinders in Brno, Made in Europe.
What guarantee do the cylinders have?
All cylinders, standard and special, come with total guarantee and technical support, spare parts available over time and one point of contact from selection to installation.
Where do you ship from?
We ship from the Czech Republic (Brno) across Europe and worldwide. Contact us with quantity and destination: we reply with offer and delivery time.
Didn’t find your answer?
Send us your question or the drawing of your mold: our technical office will reply with the right solution.
Ask our technical officeTechnical support cases